Saunier Duval Thelia 30 E Operations Instructions

Browse online or download Operations Instructions for Space heaters Saunier Duval Thelia 30 E. Saunier Duval Thelia 30 E Operating instructions User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 15
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
1
THIS IS A CAT II 2H3 APPLIANCE
01773 828100
IN WARRANTY
TECHNICAL HELPLINE
01773 828400
THELIA 30 E
Page view 0
1 2 3 4 5 6 ... 14 15

Summary of Contents

Page 1 - THELIA 30 E

1THIS IS A CAT II 2H3 APPLIANCE01773 828100IN WARRANTYTECHNICAL HELPLINE01773 828400THELIA 30 E

Page 2

10FLUE INSTALLATIONThe boiler is only suitable for top outlet flue con-nection.A - Flue to rear of boiler• Mark correct position of hole from template

Page 3 - INTRODUCTION

11FLUE INSTALLATIONFlue option Cutting length (mm) Commentsouter pipe inner pipeSide flue left e + a - 1479 e + a - 1479 maximumdimension "X&quo

Page 4 - SERVICING/MAINTENANCE

12ELECTRICAL INSTALLATIONWARNING. This boiler must be earthed.All system components shall be of an approved type.Connection of the whole electrical sy

Page 5 - BOILER SCHEMATIC

13COMMISSIONINGThe commissioning and first firing of the boiler mustonly be done by a competent person.Gas installationIt is recommended that any air

Page 6 - TECHNICAL DATA

14COMMISSIONING• Set boiler thermostat to maximum and checkthat any external controls are calling for heat.• Check that the reading on the gauge match

Page 7 - PIPING SYSTEM INSTALLATION

15Gas valve settingAll boilers are tested and factory set during manu-facture. Should it be necessary to reset a gas valve,for example after replaceme

Page 8 - BOILER LOCATION

2INSTALLATION SECTIONIntroduction... Page 3Commissioning ...

Page 9 - Cold supply

3INTRODUCTIONThe THELIA 30 E boiler is a wall mounted combina-tion boiler providing central heating and instanta-neous hot water.The boiler is of the

Page 10 - FLUE INSTALLATION

4Protection against freezingIf the boiler is to be out of use for any long periodsduring severe weather conditions, it is recom-mended that the whole

Page 11

5DIMENSIONSBOILER SCHEMATIC1-Bypass2-Loss of water pressure switch3-Pump4-Automatic air vent5-Expansion vessel6-Injector manifold7-Ignition electrode8

Page 12 - ELECTRICAL INSTALLATION

6TECHNICAL DATAHeating output adjustable from 12,7 kW to 30,2 kW43330 Btu/H to 103,040 Btu/HEfficiency 81 %Maximum heating temperature 90 °CExpansion

Page 13 - COMMISSIONING

7BOILER CONNECTIONSFrom left to right the fixing jig comprises :A-Heating return with isolating valve (m).B-Cold water inlet with isolating valve (p).

Page 14 - OPERATING SAFETY DEVICES

8BOILER LOCATIONClearancesThe position of the boiler must be such that there isadequate space for servicing.The recommended clearances are:40 mm eithe

Page 15 - SETTINGS

9Flowcontrol valveDrain pointFilling pointBypassvalve Minimum 22 mm diameterTundish(supplied)Pressurereducingvalve(supplied)DomesticwaterHeatingcircui

Comments to this Manuals

No comments